Model(s): NDX 0015, NDX 0020, NDX 0030, NDX 0045, NDX 0055, NDX 0085, NDX 0110, NDX 0135, NDX 0175, NDX 0215, NDX 0250, NDX 0340, NDX 0470, NDX 0550, NDX 0725, NDX 0950, NDX 1150, NDX 1350, NDX 1750, NDX 2000, NDX 2500, NDX 3500, NDX 4750
*Scroll to the right on mobile to see entire chart
Model |
Inlet & Outlet(1) NPT/FLG |
scfm(2) |
Nm3/h(2) |
absorbed power kW(3) |
power supply (V/ph/60Hz)(4) |
water cooled adder option available |
NDX 0015 |
½" |
15 |
24 |
0.22 |
115/1 |
No |
NDX 0020 |
½" |
20 |
32 |
0.23 |
115/1 |
No |
NDX 0030 |
½" |
30 |
48 |
0.24 |
115/1 |
No |
NDX 0045 |
½" |
45 |
72 |
0.25 |
115/1 |
No |
NDX 0055 |
¾" |
55 |
88 |
0.47 |
115/1 |
No |
NDX 0085 |
¾" |
85 |
136 |
0.49 |
115/1 |
No |
NDX 0110 |
1" |
110 |
177 |
0.92 |
115/1 |
No |
NDX 0135 |
1" |
135 |
217 |
0.92 |
115/1 |
No |
NDX 0175 |
1½" |
175 |
281 |
0.96 |
115/1 |
No |
NDX 0215 |
1½" |
215 |
345 |
0.94 |
230/1 |
No |
NDX 0250 |
1½" |
250 |
401 |
1.05 |
230/1 |
No |
NDX 0250 |
2" |
250 |
401 |
1.47 |
460/3 |
Yes |
NDX 0340 |
2" |
340 |
546 |
1.47 |
230/1 or 460/3 |
Yes |
NDX 0470 |
2" |
470 |
754 |
2.50 |
460/3 |
Yes |
NDX 0550 |
2½" |
550 |
883 |
2.60 |
460/3 |
Yes |
NDX 0725 |
2½" |
725 |
1,164 |
3.46 |
460/3 |
Yes |
NDX 0950 |
2½" |
950 |
1,525 |
3.60 |
460/3 |
Yes |
NDX 1150 |
3" |
1,150 |
1,846 |
5.04 |
460/3 |
Yes |
NDX 1350 |
3" |
1,350 |
2,167 |
6.54 |
460/3 |
Yes |
NDX 1750 |
4" Flg |
1,750 |
2,809 |
7.20 |
460/3 |
Yes |
NDX 2000 |
4" Flg |
2,000 |
3,210 |
7.20 |
460/3 |
Yes |
NDX 2500 |
6" Flg |
2,500 |
4,013 |
13.08 |
460/3 |
Yes |
NDX 3500 |
8" Flg |
3,500 |
5,618 |
14.40 |
460/3 |
Yes |
NDX 4750 |
10" Flg |
4,750 |
7,624 |
26.16 |
460/3 |
Yes |
(1) ½” to 3” are NPT threaded connections, 4” and up are supplied with ANSI fl anged connections
(2) rated flow capacity: conditions for rating dryers are in accordance with ISO7183 (Option A2). Compressed air at dryer inlet: 100 psig (7 bar) and 100°F (38°C); ambient air temperature: 100°F (38°C); operating on 60Hz power supply
(3) nominal absorbed power at rated operating conditions using 115/1/60 or 460/3/60 power supply (as applicable). For absorbed power at other voltages or conditions, contact mdi at 727-835-0678
(4) specify voltage requirements when ordering
*Scroll to the right on mobile to see entire chart
Specifications |
NDX 0015 to 0725 |
NDX 0950 to 4750 |
design operating pressure range |
0 to 232 psig |
0 to 189 psig |
maximum inlet air temperature |
158°F |
158°F |
maximum ambient temperature |
110°F - 122°F depending on refrigerant (contact mdi for details) |
➤Click Here for Pressure & Temperature Correction Factors Chart
Options
• Optional M1 (1 micron) pre-filter
• Optional M01 (0.01 micron) after-filter
*Scroll to the right on mobile to see entire chart
Model |
A (in) |
B (in) |
C (in) |
Weight (lbs) |
NDX 0015 |
15" |
18" |
17" |
55 |
NDX 0020 |
15" |
18" |
17" |
62 |
NDX 0030 |
15" |
18" |
17" |
70 |
NDX 0045 |
15" |
18" |
17" |
77 |
NDX 0055 |
15" |
20" |
19" |
84 |
NDX 0085 |
15" |
20" |
19" |
92 |
NDX 0110 |
16" |
29" |
26" |
143 |
NDX 0135 |
16" |
29" |
26" |
143 |
NDX 0175 |
16" |
29" |
26" |
152 |
NDX 0215 |
16" |
34" |
30" |
196 |
NDX 0250 |
16" |
34" |
30" |
222 |
NDX 0250 |
18" |
47" |
35" |
253 |
NDX 0340 |
18" |
47" |
35" |
253 |
NDX 0470 |
18" |
47" |
35" |
297 |
NDX 0550 |
18" |
47" |
35" |
319 |
NDX 0725 |
18" |
47" |
35" |
397 |
NDX 0950 |
23" |
47" |
40" |
712 |
NDX 1150 |
23" |
47" |
40" |
771 |
NDX 1350 |
23" |
47" |
40" |
882 |
NDX 1750 |
40" |
73" |
64" |
1,433 |
NDX 2000 |
40" |
73" |
64" |
1,480 |
NDX 2500 |
40" |
73" |
64" |
1,808 |
NDX 3500 |
47" |
102" |
75" |
3,086 |
NDX 4750 |
47" |
102" |
75" |
4,078 |
Click Here to view the mdi Line Sheet.