Nano N2 Series
GEN2 PLUS nitrogen generators

99% to 99.999% purity
For higher purity applications the GEN2 plus range of nitrogen generators add an integrated regenerative dryer cartridge which eliminates the need for a separate desiccant dryer. This innovative feature significantly reduces purge loss and pressure drop while allowing for higher outlet purity levels.

Call us TODAY at 727-835-0678 or
Toll Free at 800-761-4298

Request A Quote!

Model(s): GEN2 1110-PLUS, GEN2 2110-PLUS, GEN2 3110-PLUS, GEN2 2130-PLUS, GEN2 3130-PLUS, GEN2 4130-PLUS, GEN2 6130-PLUS, GEN2 8130-PLUS, GEN2 10130-PLUS, GEN2 12130-PLUS

*Scroll to the right on mobile to see entire chart
   Model
Rated Outlet
Flow1
nitrogen purity at the outlet
(max oxygen content)
99.999%
(10 ppm)
99.995%
(50 ppm)
99.99%
(100 ppm)
99.975%
(250 ppm)
99.95%
(500 ppm)
99.9%
(0.10%)
99.5%
(0.50%)
99%
(1%)
GEN2 1110-PLUS
scfh
28
54
65
85
102
117
170
201
GEN2 2110-PLUS
scfh
55
108
129
171
204
233
339
403
GEN2 3110-PLUS
scfh
83
162
194
256
307
350
509
604
GEN2 2130-PLUS
scfh
158
224
261
310
354
410
587
653
GEN2 3130-PLUS
scfh
238
336
392
466
531
615
881
979
GEN2 4130-PLUS
scfh
317
448
522
621
709
820
1175
1305
GEN2 6130-PLUS
scfh
475
671
783
931
1063
1231
1762
1958
GEN2 8130-PLUS
scfh
634
895
1044
1424
1417
1641
2349
2610
GEN2 10130-PLUS
scfh
729
1029
1201
1428
1630
1887
2702
3002
GEN2 12130-PLUS
scfh
846
1195
1394
1658
1892
2191
3136
3485
(1) at 100 psig inlet pressure and 68 - 77°F inlet temperature. For outlet flow at all other conditions refer to the correction factors or contact sales@mdisales.com

*Scroll to the right on mobile to see entire chart
   Specifications Standard Optional
design operating pressure range 87 to 174 psig 232 psig (consult mdi)2
design operating temperature range 41 to 122°F -
maximum inlet particulate 0.1 micron -
maximum inlet dew point 80°F PDP -
maximum inlet oil content 0.01 ppm3 -
maximum outlet dew point -40°F PDP4 -
supply voltage 100 - 240 VAC (50 or 60Hz) or 24VDC -
(2) 232 psig available as option.
(3) including oil vapor
(4) requires an upstream dryer. Contact mdi for assistance selecting the optimum dryer for your application


➤Click Here for Pressure & Temperature Correction Factors

Options
High Pressure
     ○ high pressure (232 psig)
         Fits GEN2 3130-PLUS - GEN2 12130-PLUS Suffix: HP
System Standby / Hibernation
     ○ includes pressure switch & inlet air solenoid valve. Allows system standby when demand is limited (requires 115/1/60 power supply)
         Fits All models Suffix: SS
Outlet Purity Control
     ○ Outlet Purity Control includes needles valve with inline flow meter1
         Fits all models Suffix: OPC
(1) for easy identification, elements are color coded. Ensure new element is the same color as the element being replaced. For element specifications and colors refer to “specifications”



Nano GEN2-PLUS Series Dimensions
*Scroll to the right on mobile to see entire chart
Model
A (in)
B (in)
C (in)
Weight (lbs)
GEN2 1110-PLUS
47.8"
15.7"
23.0"
375
GEN2 2110-PLUS
47.8"
15.7"
29.6"
437
GEN2 3110-PLUS
47.8"
15.7"
36.2"
560
GEN2 2130-PLUS
71.3"
15.7"
29.6"
589
GEN2 3130-PLUS
71.3"
15.7"
36.2"
780
GEN2 4130-PLUS
71.3"
15.7"
42.8"
972
GEN2 6130-PLUS
71.3"
15.7"
55.9"
1356
GEN2 8130-PLUS
71.3"
15.7"
69.3"
1739
GEN2 10130-PLUS
71.3"
15.7"
82.5"
2123
GEN2 12130-PLUS
71.3"
15.7"
95.6"
2507



Email this Page 

mdi
   
AirDryerTech.com is owned and operated by mdi, Manufacturers Distributor, Inc. mdi is an Authorized Pneumatech and Nano Distributor.
Click Here to view the mdi Line Sheet.